Clinical application of two-piece zirconia implants

14 February, 2022 / clinical
 Professors Chen, André; Chevalier, Jérôme; Fischer, Jens; Gahlert, Michael; Kohal, Ralf; Özcan, Mutlu; Payer, Michael; Piconi, Corrado; Zechner, Werner; & Drs Maier, Frank; Röhling, Stefan; Tartsch, Jens  

Background of zirconia oral implants

The development of high-performance ceramics – like zirconia – has provided new, metal-free treatment options for both patients and practitioners. Due to its superior biomechanical and biocompatible properties, zirconium dioxide (zirconia, ZrO2) has pre-vailed over other oxide ceramics and has been used in dentistry for about 25 years. In comparison with other oxide ceramics (e. g. alumina), zirconia shows superior biomechanical properties such as high fracture toughness and bending strength1 that give zirconia implants the ability to withstand oral occlusal forces.2, 3 Thus, zirconia as implant material has successfully been established on the market as a reliable alternative to titanium in implant dentistry.4

Ceramic implants made of zirconia are not only the focus of current scientific research, also the desire of patients for metal-free, respectively full ceramic dental rehabilitations, is becoming increasingly important: ceramic implants are attractive to patients. A current interview including more than 270 patients in two countries has reported that 80% of the patients would prefer ceramic over metal implants.5

In order to establish zirconia as a reliable alternative to titanium as oral implant material, stable zirconia implants with micro-rough surfaces showing a safe and predictable capacity for osseous integration have been developed. At the beginning of 2004, the first one-piece zirconia oral implants were established on the market. Initially, creating micro-rough surface topographies on zirconia implants without compromising the bio-mechanical stability (such as fracture toughness and fatigue strength) was a challenging procedure from a technical point of view. Consequently, reduced survival rates6, 7 and numerous zirconia implant fractures were reported for this “first generation” zirconia implants.8-10 Since then, the industry has continuously improved manufacture processes to produce micro-roughened zirconia implants with reliable fracture toughness and fatigue strength that show a predictable osseointegration11 and high clinical survival rates at the level of conventionally used titanium implants mid-term.6, 12-15

Experimental studies have shown that the latest generation of zirconia implants with micro-rough surfaces show an identical hard tissue integration compared with titanium implants.11, 16-20 However, the different zirconia implant systems that are available on the market show varying surface topographies and not every company offers evidence-based data or provides information regarding the implant surface and the osseointegration performance of the appropriate product. Consequently, clinicians must scrutinise if the used zirconia implant system offers scientific data regarding the osseointegration capacity.

In the last two decades, not only surface micro-texture but also implant macro design has been adapted. Whereas the first zirconia implant systems were limited to a one-piece design, also two-piece zirconia implants are available in the meantime. This developmental process has also been strongly influenced by the predilection of clinicians for two-piece implant designs and confirms a clear trend for two-piece implant designs not only for titanium but also for zirconia implants. Nowadays, one- and two-piece zirconia implants with different designs and diameters that allow the treatment of partially and completely edentulous patients have become available on the market.

Clinical data

Due to the large number of adaptations and further developments regarding zirconia implant designs and manufacture processes in a relatively short period of time, it has become quite difficult for clinicians to assess the available clinical data in relation to the zirconia implants under investigation and to evaluate the clinical relevance of the investigated implant type and the reported results.

Various clinical studies investigating different types of zirconia implants were published in the last couple of years. However, it must be considered that some recently published clinical studies investigated zirconia implant systems that have been further developed in the meantime and that are not any longer available on the market. A meta-analysis has reported that physical properties and ongoing market availability significantly influenced the reported zirconia implant survival rates.6 In a systematic review, the authors evaluated clinical studies investigating zirconia implants that were published between 2004 and 2017. The reported one-year mean survival rates for commercially available zirconia implants (98.3%) were significantly higher compared with zirconia implants that are not any longer commercially available on the market (91.2%). In addition, a mean two-year survival rate for commercially available zirconia implants of 97.2% was evaluated whereas the zirconia implant design – one-piece compared with two-piece designs – did not significantly influence the reported survival rates. In this context, it has been shown that zirconia implant survival rates have significantly in-creased between 2004 and 2017 and that the fracture incidence of zirconia oral im-plants was significantly reduced from 3.4% to 0.2%.6 Even though meta-analyses estimating overall survival rates are currently limited to one- and two-years’ data, single studies reported longer clinical follow-up periods. Regarding commercially available zirconia implants, clinical data up to and after five years of functional loading reporting survival rates of 95% are now available.12, 14, 15, 21, 22

The data of the previously reported meta-analysis were the basis for the clinical recommendations that were created for the 6th ITI Consensus Conference.6 In this systematic review, more clinical studies investigating zirconia implants with a one-piece design were included than studies evaluating two-piece zirconia implant designs. Consequently, the main statement of the consensus conference on the clinical application of zirconia implants referred to one-piece implant designs.7 However, the data of the meta-analysis has reported that the implant design did not significantly influence the reported survival rates. Based on the currently available clinical data, it seems that the studies investigating two-piece zirconia implants report similar survival rates compared with one-piece zirconia implants.

Two-piece zirconia implants – reliable prosthetic connections

Scientific studies have not only examined the clinical performance of two-piece zirconia implant systems, but also evaluated the reliability and stability of screw-retained im-plant-abutment connections. Most recently, the stability of a titanium-zirconia screw-retained connection has been directly compared with a conventional titanium-based connection in an in vitro study. The results have shown no statistically significant differences between the investigated groups. Consequently, the authors reported: “The connection of the tested screw-retained zirconia crowns in two- piece zirconia implants is comparable to standard titanium implants in the specific in vitro testing” and: “Based on the results of the present study, the connection between crown and the two-piece zirconia implant seems to be suitable for clinical application.”23

It is particularly important to evaluate studies and implant systems individually according to the material and type of connection. For example, the stability and fracture resistance of ceramic implant systems was tested in vitro in accordance with ISO standard DIN 14801 in various studies. These studies demonstrated that the tested two-part zirconia ceramic implant systems can withstand the physiological masticatory forces in the long term and the stability is considered sufficient for clinical application.24-29

Two-piece zirconia implants – reliable clinical applications

Regardless of the available scientific studies, the question whether one- or two-piece zirconia implants are used depends not only on the preference of the dentist/surgeon, but mainly on the individual clinical situation. There are specific indications in which the use of a two-piece zirconia implant concept offers a more reliable clinical outcome compared with a one-piece implant design. For example, completely edentulous jaws, soft bone conditions or when bone augmentations are performed simultaneously with implant placement and/or when primary implant stability is hardly to achieve, respectively when uncontrolled mechanical loading of the implant must be avoided. With a one-piece implant concept, the abutment is an inherent part of the implant that penetrates the soft tissue into the oral cavity. Thus, uncontrolled early loading cannot be completely avoided. Furthermore, with one-piece implants the prosthetic superstructure has to be cemented on the implant. In addition, not every clinical situation allows placing the implant in a correct prosthetic angulation and the implant has to be inserted in an angled axis. Regarding prosthetic implant axis corrections, two-piece zirconia implant concepts offer more options than one-piece concepts due to the fact, that individually designed abutments can be fabricated.

Moreover, cementation of the pros-thetic superstructures can be avoided since two-piece zirconia implant concepts allow for the fabrication of reversibly screw-retained prosthetic reconstructions. Thus, pros-thetic “flexibility” and “reversibility” must be emphasized in many clinical situations. Therefore, the use of two-piece zirconia implant concepts – as with titanium implants – has become indispensable in everyday clinical practice. So far, more clinical studies are available that investigate one-piece compared with two-piece implant concepts. However, based on the clinical data available so far, meta-analyses have reported that the zirconia implant concept – one-piece compared with two-piece – did not significantly influence the clinical survival rates up to 5.1 years (mean follow up: 2.4 years).6 Single studies investigating two-piece zirconia implant designs even reported clinical data up to and after 6.7 years of functional loading.30, 31

Summary and Conclusion

Based on the scientific data available to date, micro-rough zirconia implant surfaces show osseointegration capacity compared to their micro-rough titanium implants counterparts.11, 16-20 This applies also to one-piece and two-piece ceramic implants, since the material, the implant geometry and the surface design do not differ between one- and two-piece implants received from the same manufacturer. Moreover, scientific data supports that – depending of course on the design and material type – two-piece zirconia implant connections can withstand oral masticatory forces.23-29 Consequently, based on the currently available scientific data, the two-piece zirconia implant concept can be recommended for clinical application after correct diagnostic evaluation and appropriate patient information.

References

1Christel P, Meunier A, Heller M, Torre JP, Peille CN. Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. Journal of biomedical materials research 1989;23:45-61.

2Andreiotelli M, Kohal RJ, Author A, Department o, Prosthodontics SoDA-LUF, Hugstetter Str FG, et al. Fracture strength of zirconia implants after artificial aging. Clinical Implant Dentistry and Related Research 2009;11:158-166.

3Silva NR, Coelho PG, Fernandes CA, Navarro JM, Dias RA, Thompson VP. Reliability of one-piece ceramic implant. Journal of biomedical materials research Part B, Applied biomaterials 2009;88:419-426.

4Roehling S, Gahlert M. Keramische Zahnimplantate – wissenschaftliche Grundlagen und klinsiche Anwendung. Zahnmedizin up2date 2015;5:425-444.

5Gahlert M, Kniha H, Woelfler H, Jaquiéry C, Roehling S. Patient preference and knowledge of ceramic implants. Ceramic Implants 2018;2:6-9.

6Roehling S, Schlegel KA, Woelfler H, Gahlert M. Performance and outcome of zirconia dental implants in clinical studies: A meta-analysis. Clin Oral Implants Res 2018;29 Suppl 16:135-153.

7Morton D, Gallucci G, Lin WS, Pjetursson B, Polido W, Roehling S, et al. Group 2 ITI Consensus Report: Prosthodontics and implant dentistry. Clin Oral Implants Res 2018;29 Suppl 16:215-223.

8Roehling S, Woelfler H, Hicklin S, Kniha H, Gahlert M. A Retrospective Clinical Study with Regard to Survival and Success Rates of Zirconia Implants up to and after 7 Years of Loading. Clin Implant Dent Relat Res 2016;18:545-558.

9Gahlert M, Burtscher D, Grunert I, Kniha H, Steinhauser E, Author A, et al. Failure analysis of fractured dental zirconia implants. Clinical Oral Implants Research 2012;23:287-293.

10Gahlert M, Burtscher D, Pfundstein G, Grunert I, Kniha H, Roehling S. Dental zirconia implants up to three years in function: a retrospective clinical study and evaluation of prosthetic restorations and failures. Int J Oral Maxillofac Implants 2013;28:896-904.

11Roehling S, Schlegel KA, Woelfler H, Gahlert M. Zirconia compared to titanium dental implants in preclinical studies-A systematic review and meta-analysis. Clin Oral Implants Res 2019;30:365-395.

12Gahlert M, Kniha H, Weingart D, Schild S, Gellrich NC, Bormann KH. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth gaps. Clin Oral Implants Res 2016;27:e176-e184.

13Becker J, John G, Becker K, Mainusch S, Diedrichs G, Schwarz F. Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla: a prospective cohort study over 2 years. Clinical oral implants research 2017;28:29-35.

14Balmer M, Spies BC, Kohal RJ, Hammerle CH, Vach K, Jung RE. Zirconia implants restored with single crowns or fixed dental prostheses: 5-year results of a prospective cohort investigation. Clin Oral Implants Res 2020.

15Kohal RJ, Spies BC, Vach K, Balmer M, Pieralli S. A Prospective Clinical Cohort Investigation on Zirconia Implants: 5-Year Results. J Clin Med 2020;9.

16Bormann KH, Gellrich NC, Kniha H, Dard M, Wieland M, Gahlert M. Biomechanical evaluation of a microstructured zirconia implant by a removal torque comparison with a standard Ti-SLA implant. Clinical oral implants research 2012;23:1210-1216.

17Gahlert M, Roehling S, Sprecher CM, Kniha H, Milz S, Bormann K. In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae. Clin Oral Implants Res 2012;23:281-286.

18Gahlert M, Roehling S, Wieland M, Sprecher CM, Kniha H, Milz S. Osseointegration of zirconia and titanium dental implants: a histological and histomorphometrical study in the maxilla of pigs. Clinical oral implants research 2009;20:1247-1253.

19Gahlert M, Rohling S, Wieland M, Eichhorn S, Kuchenhoff H, Kniha H. A comparison study of the osseointegration of zirconia and titanium dental implants. A biomechanical evaluation in the maxilla of pigs. Clin Implant Dent Relat Res 2010;12:297-305.

20Janner SFM, Gahlert M, Bosshardt DD, Roehling S, Milz S, Higginbottom F, et al. Bone response to functionally loaded, two-piece zirconia implants: A preclinical histometric study. Clin Oral Implants Res 2018;29:277-289.

21Grassi FR, Capogreco M, Consonni D, Bilardi G, Buti J, Kalemaj Z. Immediate occlusal loading of one-piece zirconia implants: five-year radiographic and clinical evaluation. Int J Oral Maxillofac Implants 2015;30:671-680.

22Bormann KH, Gellrich NC, Kniha H, Schild S, Weingart D, Gahlert M. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up. BMC Oral Health 2018;18:181.

23Joos M, Sailer I, Filippi A, Mukaddam K, Rosentritt M, Kuhl S. Stability of screw-retention in two-piece zirconia implants: An in vitro study. Clin Oral Implants Res 2020;31:607-614.

24Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, et al. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. Materials (Basel) 2020;13.

25Joda T, Voumard B, Zysset PK, Bragger U, Ferrari M. Ultimate force and stiffness of 2-piece zirconium dioxide implants with screw-retained monolithic lithium-disilicate reconstructions. J Prosthodont Res 2018;62:258-263.

26Spies BC, Fross A, Adolfsson E, Bagegni A, Doerken S, Kohal RJ. Stability and aging resistance of a zirconia oral implant using a carbon fiber-reinforced screw for implant-abutment connection. Dent Mater 2018;34:1585-1595.

27Spies BC, Nold J, Vach K, Kohal RJ. Two-piece zirconia oral implants withstand masticatory loads: An investigation in the artificial mouth. J Mech Behav Biomed Mater 2016;53:1-10.

28Zhang F, Meyer Zur Heide C, Chevalier J, Vleugels J, Van Meerbeek B, Wesemann C, et al. Reliability of an injection-moulded two-piece zirconia implant with PEKK abutment after long-term thermo-mechanical loading. J Mech Behav Biomed Mater 2020;110:103967.

29Spies BC, Maass ME, Adolfsson E, Sergo V, Kiemle T, Berthold C, et al. Long-term stability of an injection-molded zirconia bone-level implant: A testing protocol considering aging kinetics and dynamic fatigue. Dent Mater 2017;33:954-965.

30Koller M, Steyer E, Theisen K, Stagnell S, Jakse N, Payer M. Two-piece zirconia versus titanium implants after 80 months: Clinical outcomes from a prospective randomized pilot trial. Clin Oral Implants Res 2020;31:388-396.

31Payer M, Heschl A, Koller M, Arnetzl G, Lorenzoni M, Jakse N. All-ceramic restoration of zirconia two-piece implants–a randomized controlled clinical trial. Clin Oral Implants Res 2015;26:371-376.

Categories: Feature / Magazine

Comments are closed here.

Scottish Dental magazine